TJ-CEO
2021 , Vol 16 , Num 4
Haptic Dislocation Mimicking Ciliary Body and Iris Mass
1MD., Boğazlıyan State Hospital, Clinic of Ophthalmology, Yozgat, Turkey2MD., Ünye State Hospital, Clinic of Ophthalmology, Ordu, Turkey
3Prof., Ankara University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey DOI : 10.37844/glauc.cat.2021.16.36 A 79-year-old male applied to our clinic for routine examination. Slit-lamp examination revealed posterior chamber intraocular lens (IOL), iris elevation at 9 o\'clock and narrowing of anterior chamber angle in the right eye. Although the clinical findings were suggestive for ciliary body mass, ultrasonic biomicroscopy (UBM) demonstrated IOL haptic dislocation at the elevated area. UBM imaging is an important imaging modality that allows visualization of posterior chamber and provides information in the differential diagnosis of localized bulging of the iris. Keywords : Iris elevation, Iris bulging, Haptic dislocation, Ultrasonic biomicroscopy